閘門異常升壓防護措施發(fa)表時(shi)間:2020-01-09 09:17 從(cong)(cong)設計、安裝、調試等方面入手,從(cong)(cong)根本上消除中(zhong)腔異常升壓是完全有可能(neng)的,歸納常用(yong)(yong) 3 套方案供廣大用(yong)(yong)戶參考: ①:閥(fa)門(men)內部開設泄壓孔 解(jie)決中(zhong)(zhong)腔(qiang)(qiang)(qiang)異(yi)常升(sheng)(sheng)壓(ya)(ya)(ya)的(de)根本是平衡中(zhong)(zhong)腔(qiang)(qiang)(qiang)壓(ya)(ya)(ya)力,開設泄(xie)壓(ya)(ya)(ya)孔是最經(jing)濟有效的(de)方案(an),下圖所示分(fen)別為在上(shang)游側閘板及進口側閥座(zuo)外圓開設了泄(xie)壓(ya)(ya)(ya)孔,當中(zhong)(zhong)腔(qiang)(qiang)(qiang)壓(ya)(ya)(ya)力升(sheng)(sheng)高時,中(zhong)(zhong)腔(qiang)(qiang)(qiang)壓(ya)(ya)(ya)力會自(zi)動(dong)向上(shang)游側泄(xie)放,始終保持(chi)中(zhong)(zhong)腔(qiang)(qiang)(qiang)壓(ya)(ya)(ya)力與上(shang)游側壓(ya)(ya)(ya)力相等,從而避免異(yi)常升(sheng)(sheng)壓(ya)(ya)(ya)的(de)發生。 、 ②:閥門安裝(zhuang)外旁路泄(xie)壓 對已出廠的閥(fa)門(men)可采用安裝(zhuang)時(shi)外(wai)旁(pang)路及外(wai)設泄壓閥(fa)降(jiang)低中(zhong)腔壓力,如下圖所示 采用外設帶截(jie)止閥(fa)的旁路聯(lian)通中腔(qiang)與上(shang)游側,當主(zhu)閘板關(guan)閉(bi)后截(jie)止閥(fa)可關(guan)閉(bi)(視中腔(qiang)溫度(du)變化情況,過(guo)高時(shi)(shi)須開啟)。當開啟主(zhu)閘閥(fa)時(shi)(shi),應(ying)先行開啟旁路截(jie)止閥(fa),降低中腔(qiang)壓力(li)后再啟動主(zhu)閘閥(fa)。 ③:閥門外(wai)部安裝專用泄壓(ya)閥 如上圖所示為在閘閥中腔外設泄壓閥控制壓力范圍,設定泄壓閥的排放壓力為主閥門的額定工作壓力,當中腔超壓時,自動排放到設定壓力,從而維護主閘閥的安全運行。 圖(tu)上為泄壓(ya)閥(fa)(fa)的結構設計圖(tu)(可供參(can)考)。泄壓(ya)閥(fa)(fa)前安(an)裝了截(jie)止閥(fa)(fa),便(bian)于(yu)泄壓(ya)閥(fa)(fa)的調(diao)整與(yu)檢修(xiu)。泄壓(ya)閥(fa)(fa)的壓(ya)力設定通常可按 1.33PN 考慮(PN 為系統閥(fa)(fa)門的公稱應力)。 除此(ci)之外,閥(fa)門調(diao)試(shi)時,尤其是(shi)電動(dong)閥(fa)調(diao)試(shi)時,應注意關閉(bi)(bi) 行程及力矩(ju)的(de)控制(zhi),盡可能將關閉(bi)(bi)力矩(ju)調(diao)小些,防止(zhi)楔(xie)死閘(zha)板;高(gao)溫(wen)閥(fa)門應考慮高(gao)溫(wen)狀態閥(fa)桿熱脹引起(qi)的(de)閘(zha)板楔(xie)死,建議高(gao)溫(wen)高(gao)壓大(da)口(kou)徑(jing)閘(zha)閥(fa)調(diao)試(shi)時,閘(zha)板到位后適當后退閥(fa)桿,避免真正咬(yao)死事(shi)故(gu)的(de)發生(sheng)。 |